Delivery: 33333 Edit Records Home
AL SAHEL S PLASTICS
IN HOUSE TEST REPORT
Upvc pipe size: Diameter 225 MM PN 10 S/W
Date: 25/09/2026
B.NO: 20251230-M8-B-12
D. N. NO: 33333
Test BSEN 1452 test
Requirements.
Test Results
Mean Outside Diameter(mm) Min: 225.0      Max: 225.70 Mean : 225.34
Wall Thickness Min: 8.60      Max: 9.70 Min: 8.71    Max: 9.12
Length Meters      Min: 6.0 6.0
Tensile Strength ISO: 6259 ≥ 45 Mpa. 47.47
Elongation @ Break ISO: 6259 ≥ 80 % 88.12
Resistance to Acetone ( ISO : 3472) No Delimitation or Disintegration Should Occur - 2 hours NO DELAMINATION
VICAT SOFTENING POINT (ISO:2507) MIN : 79 Deg. C 84.27
OPACITY( ISO: 7686) LIGHT PASSING SHALL NOT MORE THAN 0.2% 0.01%
DENSITY TEST (1183-1,2) MIN: 1360KG/M3
MAX: 1450 KG/M3
1,429
Heat Reversion Test : (%) ISO: 2505 Change in length should not more than 5% -3.35%
HYDROSTATIC PRESSURE TEST: (ISO: 1167-1,2) PIPE SHOULD WITHSTAND 34 BARS PRESSURE FOR 1HOUR AS PER PRESSURE TEST CALCULATION. PIPE WITHSTOOD 35 BARS PRESSURE FOR 1 HOUR
Impact Resistance( ISO: 3127) TRUE IMPACT RATE SHALL NOT BE MORETHAN 10% TIR BELOW 10%
(0/25 PASSED)
Test Assessment: The pipe sample 225 mm PN- 10 S/W tested as per BSEN: 1452.
The sample meets all requirements as per the Standards.
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
VICAT SOFTENING TEMPERATURE TEST
TESTING STANDARD: BSEN 1452-2
TEST METHOD: AS PER ISO: 2507
U-PVC PIPE SAMPLE SIZE AND CLASS: 225 MM PN 10 (8.60 MM W.T)   B.NO: 20251230-M8-B-12
NUMBER OF SAMPLES : 3
TEST REQUIREMENTS :      VICAT SOFTENING TEMPERATURE SHOULD NOT BE LESS THAN 79 DEG.C
SAMPLE 1 : 84.86 Deg.C          SAMPLE 2: 83.90 Deg.C          SAMPLE 3: 84.06 Deg.C
AVERAGE : 84.27 Deg.C
TEST ASSESSMENT: SAMPLE PASSED
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
OPACITY TEST
TESTING STANDARD: BSEN 1452-2
TEST METHOD: AS PER ISO: 7686
U-PVC PIPE SAMPLE SIZE AND CLASS: 225 MM PN 10 (8.60 MM W.T)   B.NO: 20251230-M8-B-12
SAMPLE SIZE: 45 MM X 45 MM
NUMBER OF SAMPLES : 2
TEST REQUIREMENTS :      MAXIMUM LIGHT PASSING : 0.20%
SAMPLE 1: 0.01%              SAMPLE 2: 0.00%
AVERAGE : 0.01%
TEST ASSESSMENT: SAMPLE PASSED
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
DENSITY TEST
TESTING STANDARD: BSEN 1452-2
TEST METHOD: AS PER ISO: 1183-1
U-PVC PIPE SAMPLE SIZE AND CLASS: 225 MM PN 10 (8.60 MM W.T)   B.NO: 20251230-M8-B-12
NUMBER OF SAMPLES : 3
TEST REQUIREMENTS :      MINIMUM: 1,360 Kg/m3      MAXIMUM : 1,450 Kg/m3
SAMPLE 1: 1,430 Kg/m3          SAMPLE 2: 1,422 Kg/m3          SAMPLE 3: 1,435 Kg/m3
AVERAGE DENSITY : 1,429 Kg/m3
TEST ASSESSMENT: SAMPLE PASSED
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
REVERSION TEST
TESTING STANDARD: BSEN 1452-2
TEST METHOD: AS PER ISO: 2507
U-PVC PIPE SAMPLE SIZE AND CLASS: 225 MM PN 10 (8.60 MM W.T)   B.NO: 20251230-M8-B-12
NUMBER OF SAMPLES : 3
TEST REQUIREMENTS :      CHANGE IN LENGTH SHOULD NOT ALTERED MORETHAN 5%
SAMPLE 1 : -3.52 %          SAMPLE 2: -3.52 %          SAMPLE 3: -3.01%
AVERAGE SHRINKAGE : -3.35 %
TEST ASSESSMENT: SAMPLE PASSED
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
IN HOUSE LAB TESTING DOCUMENTS
HYDROSTATIC PRESSURE TEST ( AS PER ISO: 1167-1,2)
TEST STANDARD SPECIFICATION: BSEN 1452-2
UPVC PIPE SAMPLE SIZE : 225 MM PN 10 ( 8.60 MM W.T)   B.NO : 20251230-M8-B-12
TEST CONDITIONS: MINIMUM TIME FRAME : 1 hour @ 20 Deg.C
TEST REQUIREMENTS: Pipe Should withstand 34.40 Bars as per the pressure test calculation. During the test pipe without Burst and shape change .
TEST RESULT : Pipe sample withstood 34.9 Bar Pressure for 1 hour without Burst.
REMARKS    :    SAMPLE PASSED .
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
IN HOUSE LAB TESTING DOCUMENTS
IMPACT TEST ( AS PER ISO: 3127 ) Round -Clock Method
TEST STANDARD SPECIFICATION: BSEN 1452-2
TEST REQUIREMENTS : TIR BELOW 10% ( TRUE IMPACT RATE)
UPVC PIPE SAMPLE SIZE AND CLASS : 225 MM PN 10 ( 8.60 MM W.T)
BATCH NUMBER : 20251230-M8-B-12          SIZE OF THE SAMPLE : 200 MM (+/- 10 MM) LONG
NUMBER OF SAMPLES USED : 3      NUMBER OF STROKES : 25      NUMBER OF FAILURES : 0/25
MASS FALLING HEIGHT : 1.81 METERS          FALLING WEIGHT ( IN KGS ) : 2.49 kgs
CONDITION OF SAMPLE @ : @ 0 Deg.C          DIMENSION FOR THE NOSE OF THE STRIKER - D 90
TEST RESULTS :    TIR BELOW 10%
REMARKS : SAMPLE PASSED .
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
UPVC PIPE PHYSICAL DIMENSIONS CHART.
Item: UPVC PIPE :          SIZE : 225 MM PN 10 (8.60 MM W.T) .
D.O.M: 30.12.2025          BATCH NUMBER : 20251230-M8-B-12
STANDARD AS PER BSEN 1452
S.NO REQUIREMENTS WALL THICKNESS OF THE PIPE ( MM )
MINIMUM: 8.60 MM    MAXIMUM : 9.70 MM
REQUIREMENTS OUTSIDE DIAMETER OF THE PIPE (MM)
MINIMUM: 225.00 MM    MAXIMUM: 225.70 MM
COMPLY /
NOT COMPLY
READING 1 (MM) READING 2 (MM) MEAN WALL THICKNESS (MM) STATUS AVERAGE OD (MM) STATUS
1 8.79 9.09 8.94 COMPLY 225.34 COMPLY COMPLIED
2 8.74 8.95 8.85 COMPLY 225.29 COMPLY COMPLIED
3 8.71 8.93 8.82 COMPLY 225.35 COMPLY COMPLIED
4 8.86 8.87 8.87 COMPLY 225.44 COMPLY COMPLIED
5 8.80 9.03 8.92 COMPLY 225.38 COMPLY COMPLIED
6 8.75 9.09 8.92 COMPLY 225.21 COMPLY COMPLIED
7 8.78 8.88 8.83 COMPLY 225.44 COMPLY COMPLIED
8 8.81 9.12 8.97 COMPLY 225.39 COMPLY COMPLIED
9 8.76 8.97 8.87 COMPLY 225.28 COMPLY COMPLIED
10 8.80 9.00 8.90 COMPLY 225.23 COMPLY COMPLIED
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
IN HOUSE LAB TESTING DOCUMENTS
UPVC PIPE TENSILE STRENGTH TEST ( AS PER ISO: 6259 )
TEST STANDARD SPECIFICATION : BSEN 1452-2
UPVC PIPE SAMPLE SIZE: 225 MM PN 10 ( 8.60 MM W.T)   B.NO : 20251230-M8-B-12
NUMBER OF SAMPLES STRIPES : 5      TEST SPEED : 5 MM +/- 1 MM (PER MINUTE)
TEST REQUIREMENTS FOR UPVC PIPE SAMPLE: MINIMUM 45 Mpa
NUMBER OF SAMPLE TESTED : 5 NUMBERS
SAMPLE WALL THICKNESS (MM) WIDTH (MM) VALUE (IN Mpa)
SAMPLE NO 1 : 8.82 6.0 47.30
SAMPLE NO 2 : 8.85 6.0 47.30
SAMPLE NO 3 : 8.87 6.0 47.22
SAMPLE NO 4 : 8.82 6.0 47.59
SAMPLE NO 5 : 8.92 6.0 47.95
TEST RESULT :    AVERAGE TENSILE STRESS VALUE : 47.47 Mpa
REMARKS    :    SAMPLE PASSED .
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
ACETONE TEST
TESTING SPECIFICATION STANDARD: BSEN 1452-2
TEST METHOD: AS PER ISO: 3472
U-PVC PIPE SAMPLE SIZE AND CLASS : 225 MM PN 10 ( 8.60 MM W.T)   B.NO: 20251230-M8-B-12
SAMPLE SIZE: 100 MM LONG X 25 MM WIDTH
NUMBER OF SAMPLES : 3
TEST REQUIREMENTS :      NO DELAMINATION AND INTEGRATION
SAMPLE 1:      NO DELAMINATION

SAMPLE 2:      NO DELAMINATION

SAMPLE 3 :      NO DELAMINATION
TEST ASSESSMENT: NO DELAMINATION , SAMPLE PASSED
Date: 25/09/2026
Ref: NBHI/591
Delivery No: 33333
AL SAHEL S PLASTICS
IN HOUSE LAB TESTING DOCUMENTS
UPVC PIPE ELONGATION TEST ( AS PER ISO: 6259 )
TEST STANDARD SPECIFICATION: BSEN 1452-2
UPVC PIPE SAMPLE SIZE: 225 MM PN 10 ( 8.60 MM W.T)   B.NO : 20251230-M8-B-12
NUMBER OF SAMPLES STRIPES : 5      TEST SPEED : 5 MM +/- 1 MM (PER MINUTE)
TEST REQUIREMENTS FOR UPVC PIPE SAMPLE : MINIMUM 80 %
NUMBER OF SAMPLE TESTED : 5 NUMBERS
SAMPLE WALL THICKNESS (MM) WIDTH (MM) VALUE ( IN % )
SAMPLE NO 1 : 8.72 6.0 89.50
SAMPLE NO 2 : 8.85 6.0 87.67
SAMPLE NO 3 : 8.85 6.0 88.96
SAMPLE NO 4 : 8.79 6.0 87.21
SAMPLE NO 5 : 8.84 6.0 87.28
TEST RESULT :    AVERAGE ELONGATION : 88.12 %
REMARKS    :    SAMPLE PASSED .